122 lines
3.5 KiB
Nix
122 lines
3.5 KiB
Nix
{ pkgs, lib, ... }:
|
|
let
|
|
tasmota_plug = name: topic:
|
|
{ platform = "mqtt";
|
|
inherit name;
|
|
state_topic = "/bam/${topic}/stat/POWER1";
|
|
command_topic = "/bam/${topic}/cmnd/POWER1";
|
|
availability_topic = "/bam/${topic}/tele/LWT";
|
|
payload_on= "ON";
|
|
payload_off= "OFF";
|
|
payload_available= "Online";
|
|
payload_not_available= "Offline";
|
|
};
|
|
espeasy_dht22 = name: [
|
|
{ platform = "mqtt";
|
|
name = "${name} DHT22 Temperature";
|
|
device_class = "temperature";
|
|
state_topic = "/bam/${name}/dht22/Temperature";
|
|
availability_topic = "/bam/${name}/tele/LWT";
|
|
payload_available = "Online";
|
|
payload_not_available = "Offline";
|
|
}
|
|
{ platform = "mqtt";
|
|
device_class = "humidity";
|
|
name = "${name} DHT22 Humidity";
|
|
state_topic = "/bam/${name}/dht22/Humidity";
|
|
availability_topic = "/bam/${name}/tele/LWT";
|
|
payload_available = "Online";
|
|
payload_not_available = "Offline";
|
|
}];
|
|
espeasy_ds18 = name:
|
|
{ platform = "mqtt";
|
|
name = "${name} DS18 Temperature";
|
|
state_topic = "/bam/${name}/ds18/Temperature";
|
|
availability_topic = "/bam/${name}/tele/LWT";
|
|
payload_available = "Online";
|
|
payload_not_available = "Offline";
|
|
};
|
|
in {
|
|
networking.firewall.allowedTCPPorts = [ 8123 ];
|
|
nixpkgs.config.permittedInsecurePackages = [
|
|
"homeassistant-0.65.5"
|
|
];
|
|
|
|
services.home-assistant = {
|
|
enable = true;
|
|
config = {
|
|
homeassistant = {
|
|
name = "Bureautomation";
|
|
time_zone = "Europe/Berlin";
|
|
};
|
|
|
|
mqtt = {
|
|
broker = "localhost";
|
|
port = 1883;
|
|
client_id = "home-assistant";
|
|
keepalive = 60;
|
|
protocol = 3.1;
|
|
birth_message = {
|
|
topic = "/bam/hass/tele/LWT";
|
|
payload = "Online";
|
|
qos = 1;
|
|
retain = true;
|
|
};
|
|
will_message = {
|
|
topic = "/bam/hass/tele/LWT";
|
|
payload = "Offline";
|
|
qos = 1;
|
|
retain = true;
|
|
};
|
|
};
|
|
switch = [
|
|
(tasmota_plug "Bauarbeiterlampe" "plug")
|
|
(tasmota_plug "Blitzdings" "plug2")
|
|
(tasmota_plug "Fernseher" "plug3")
|
|
(tasmota_plug "Pluggy" "plug4")
|
|
];
|
|
binary_sensor = [
|
|
{ platform = "mqtt";
|
|
device_class = "motion";
|
|
name = "Motion";
|
|
state_topic = "/bam/easy2/movement/Switch";
|
|
payload_on = "1";
|
|
payload_off = "0";
|
|
availability_topic = "/bam/easy2/tele/LWT";
|
|
payload_available = "Online";
|
|
payload_not_available = "Offline";
|
|
}
|
|
];
|
|
sensor =
|
|
(espeasy_dht22 "easy1") ++
|
|
(espeasy_dht22 "easy2") ++
|
|
[ (espeasy_ds18 "easy3" )
|
|
{ platform = "luftdaten";
|
|
name = "Ditzingen";
|
|
sensorid = "5341";
|
|
monitored_conditions = [ "P1" "P2" ];
|
|
}
|
|
{ platform = "influxdb";
|
|
queries = [
|
|
{ name = "mean value of feinstaub P1";
|
|
where = '' "node" = 'esp8266-1355142' '';
|
|
measurement = "feinstaub";
|
|
database = "telegraf";
|
|
field = "P1";
|
|
}
|
|
{ name = "mean value of feinstaub P2";
|
|
where = '' "node" = 'esp8266-1355142' '';
|
|
measurement = "feinstaub";
|
|
database = "telegraf";
|
|
field = "P2";
|
|
}
|
|
];
|
|
}
|
|
];
|
|
frontend = { };
|
|
http = { };
|
|
feedreader.urls = [ "http://www.heise.de/security/rss/news-atom.xml" ];
|
|
};
|
|
};
|
|
}
|